Minimum Order Quantity | 1 Unit |
Usage/Application | Clinical |
Brand | MODERN AESTHETICS |
Frequency | 4MHZ |
Max Output | HF MONOPOLAR 150WATTS ON 400 OHM LOAD |
Warranty | 1year |
POWER CONSUMPTION | 150WATTS |
POWER INPUT | 220VOLT+-5% |
FULGURATION | 100WATTS ON 1000 OHM |
MAXOUTPUT | HF BIPOLAR 100WATTS ON 100 OHM LOAD |
The TechNIQue of Radio Surgery involves the passages of high Frequency radio waves(4mhz-megahertz) through soft tissue to cut, coagulate,or remove the tissue. soft tissue resistance to these radio waves causes the cellular water in the soft tissue to heat ,which produces steam, an results in cellular molecular dissolution or lndicedual tissue cells.
The surgeon uses a hand piece with an active electrode (different type of electrodes for different applications) lo transmit the radlo waves.The radio waves are focussed on the tissue by an antenna plate (patient plate that is positioned Behind the tissue In contact with patient's skin.
Radio surgery in general practise has many advantages over. Conventional surgical techniques particularly dermatological, Plastic and eye lid surgery.ENT, Dental.quicker operating time rapid healing ,less tiSsue damage and less post operative discomfort have been observed and is wider use in hospital practise is reoommended
Specifications:
Power input: 220volt + 5%
Power consumption 150walts
Frequency: 4MHZ
Maximum output:
HF Monopolar 150Walts on 400 ohmload
HF Blpolar 100walts on 100 ohm load
Fulguration 100watts on 1000 ohm
Minimum Order Quantity | 1 Unit |
Usage/Application | Hospital |
Type Of Equipment | Electro Cautery |
Brand | MODERN AESTHETICS |
Display Type | FND Display |
Warranty | 1year |
Weight Kg | 5.0 Kg |
Size/Dimension | 14" x 12" x 4.5" |
I Deal In | New Only |
Power Watt | 100WATT |
Input Voltage | 110 to 240 VAC 50 HZ |
digital electro surgical cautery 100w
power – 100w
model – digital
capability dermatological plastic, ent surgery
excellent quality high frequence device
specifications
| max. Power (watts) | rated load (ohms) |
operating frequency | 666 khz | - |
display | fnd display | - |
pure cut | 100w | 500 |
blend 1 | 100w | 500 |
blend 2 | 100w | 500 |
endocut | 100w | 500 |
coagulation |
|
|
fulguration | 150w | 500 |
spray | 120w | 500 |
desiccation/soft. | 100w | 500 |
bipolar |
|
|
biopolar coagulation macro | 60w | 100 |
biopolar coagulation micro | 90w | 100 |
biopolar coagulation & cut | 40w | 100 |
dimension (wxhxd) | 14” x 12” x 4. 5” |
|
weight | 5. 0 kg |
|
input voltage | 110 to 240 vac 50 hz |
Minimum Order Quantity | 1 Unit |
Brand | MODERN AESTHETICS |
Type Of Equipment | ELECTRO SURGICAL DEVICE |
Usage/Application | Hospital |
Weight | 5KG |
Warranty | 1year |
Size/Dimension | 14" x 12" x 4.5" |
I Deal In | New Only |
Input Voltage | 110 to 240 VAC 50 HZ |
OPERATING FREQUENCY | 666 KHZ |
DIGITAL ELECTRO SURGICAL DEVICE 300W
POWER – 300W
MODEL – DIGITAL
CAPABILITY ALL SURGERY
EXCELLENT QUALITY HIGH FREQUENCE DEVICE
Specifications
| MAX. POWER (WATTS) | RATED LOAD (OHMS) |
Operating Frequency | 666 KHZ | - |
Display | FND Display | - |
Pure Cut | 300w | 500 |
Blend 1 | 250w | 500 |
Blend 2 | 200w | 500 |
Endocut | 100w | 500 |
Coagulation |
|
|
Fulguration | 200w | 500 |
Spray | 150w | 500 |
Desiccation/Soft. | 100w | 500 |
Bipolar |
|
|
Biopolar Coagulation Macro | 60w | 100 |
Biopolar Coagulation Micro | 90w | 100 |
Biopolar Coagulation & Cut | 40w | 100 |
Dimension (WxHxD) | 14” x 12” x 4.5” |
|
Weight | 5.0 Kg |
|
Input Voltage | 110 to 240 VAC 50 HZ |
|
*Your information is safe with us.
Minimum Order Quantity | 1 Unit |
Usage/Application | Clinical |
Brand | MODERN AESTHETICS |
Frequency | 4MHZ |
Max Output | HF MONOPOLAR 150WATTS ON 400 OHM LOAD |
POWER CONSUMPTION | 150WATTS |
POWER INPUT | 220VOLT+-5% |
FULGURATION | 100WATTS ON 1000 OHM |
MAX | HF BIPOLAR 100WATTS ON 100 OHM LOAD |
The TechNIQue of Radio Surgery involves the passages of high Frequency radio waves(4mhz-megahertz) through soft tissue to cut, coagulate,or remove the tissue. soft tissue resistance to these radio waves causes the cellular water in the soft tissue to heat ,which produces steam, an results in cellular molecular dissolution or lndicedual tissue cells.
The surgeon uses a hand piece with an active electrode (different type of electrodes for different applications) lo transmit the radlo waves.The radio waves are focussed on the tissue by an antenna plate (patient plate that is positioned Behind the tissue In contact with patient's skin.
Radio surgery in general practise has many advantages over. Conventional surgical techniques particularly dermatological, Plastic and eye lid surgery.ENT, Dental.quicker operating time rapid healing ,less tiSsue damage and less post operative discomfort have been observed and is wider use in hospital practise is reoommended
Specifications:
Power input: 220volt + 5%
Power consumption 150walts
Frequency: 4MHZ
Maximum output:
HF Monopolar 150Walts on 400 ohmload
HF Blpolar 100walts on 100 ohm load
Fulguration 100watts on 1000 ohm
Minimum Order Quantity | 1 Unit |
Preferred Treatment Method | Surgery |
Preferred Location | delhi |
Patient Insured | No |
Mole Removal Kit,Professional Spot Removal Machine, Portable Age Spots Removal Device
About the productThe Portable Beauty Pen Kit is extremely lightweight, wireless, portable, and charges by USB so you can easily use it and recharge it anywhere. iNtelligent Processing:Removal spot without hurting the normal skin and without blooding, easy carry and easy operationFreckle remover pen has 3 adjustable scan spot power outputs for different treatment, which is reliable, useful and convenient. Lower level for small age spot, mole remover / The second level for middles area /The Third level for keloid scars removerFreckle remover machine erfect for Mole, Skin tag, Nevus, Freckles, Dark Spot, Birth Mark, Skin Pigmentation, Age Spots.. Treating and restoration of connective tissuesUsing German microcomputer technology, Ionization of carbonization, Non-ablative treatment and Fast healing process without huring the normal skinUsing electric ion carbonation functions and instantly sweep freckles, age spot,flat moles,etc,can be achieved quickly without bleeding, safe and side effects of medical cosmetic results Product description
How To Use:
1. Power Button(On/Off): Long press the button for 3 seconds to turn on which shows the power and gear position(default 1st), the red power is for default. If no operation for 30 seconds, the screen will be off. Short press (On/Off) key to toggle output power pre one cell represents a file, quickly press twice (green on behalf of the power).
2. Working Key(Out): Press out key to start working, the pen indicate normal operation, release to stop working.
3. Protection: Long press(Out) button for 2 minutes to stop the output device, if need to continue to work, lease the key and press it again.
4. Display and Charge Description: the three green light that the battery power is 100%, the second light is 75%, the first light is 50%, the last green light flashing is 25%, when the 5V Charging access device automatically shut down, green light is full when the charge is complete.
Attention:
1. As the device can produce high temperature effects in an instant when not in use please avoid children to play.
2. 30 days, it is best not to use too much wash the affected area.(the simple care on line)can not scrub, can not artificially make the crust off.
3. when itchy scab at the time( meat tenderizer anagen) do not use the clutch in addition, the right to be 20-30 days, scab off on their own.
4. The recovery period is 3-6 month do not eat ginger (after restoring skin is not so flat) beef (will faint red) sauce (there will be a touch if black ) during the recovery period.
Package Included:
1 x Spot/Mole/Tattoo/Wart Removal/Speckle Nevus Removal Pen
1 x Big Needle
1 x USB Line
5 x Small Needle
1 x Manual
Product Dimensions: 1.3 x 1.3 x 6.5 inche
Spot Removal Pen, Remove Mole , Warts & Small Tattoo
3.8/5
Rated by 29 Users