Modern Aesthetics

Vaishali, Ghaziabad, Uttar Pradesh

GST No. 07BVMPS4622Q1ZQ

Send Email
Call 08041949941 81% Response Rate
Search

Home » Our Products » Fractional CO2 laser Machine


Fractional CO2 laser Machine

Our range of products include 10600nm fractional co2 laser beauty machine and multifunctional fractional co2 laser with v care system.

10600nm Fractional CO2 Laser Beauty Machine

REQUEST CALLBACK

10600nm Fractional CO2 Laser Beauty Machine
  • 10600nm Fractional CO2 Laser Beauty Machine
  • 10600nm Fractional CO2 Laser Beauty Machine
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 5 Lakh / UnitGet Latest Price

Product Details:
Minimum Order Quantity1 Unit
Wavelength10600
Power220V/110V
Weight60Kg
Control SystemAIR CIRCULATION
Dimension65*48*117cm
BrandModern Aesthetics
DISTANCE0.1-2.6MM
OPTICAL BEAM QUALITYTEM00
SPOT SIZE0.02-0.05MM2

10600nm Fractional CO2 Laser beauty machine(with skin cooling function)

1.Principle:Vaginal tightening laser is the use of water uptake 10600nm gold standard laser,using a three-dimensional lattice technology and 360-degree circular emission perfect combination of technology, to produce 50-70 degrees Celsius in a controlled depth of the vaginal mucosa, stimulate lamina propria and myometrium newborn fibroblasts, and damaged collagen fibers, elastic fibers, such as restructuring, so as to achieve vaginal wall thickening and tightening of the vagina so that firmness, sensitivity enhancement, vagina tight as ever.

Vaginal tightening laser does not produce skin burns due to high temperature, each capable of Homogeneous heat, acting on a few hundred nanometers thickness Mucosa organization.

3.system Parameter adjustment

Fractional model energy parameter reference tablePower(W)8~15,According to the degree of skin and repair itself the ability to choose, is generally used 9.Duration(ms)1.0~2.0,1.0 is generally used, the greater the residence time, the laser acts on the skin longer, whereas shorter.Repeat(ms)1.0~2.0,1.0 is generally used, the greater the interval, the faster the laser light, on the contrary, the slower.Distance(mm)1.0~2.0,1.0 is generally used, the greater the spacing, the laser effects on the skin point of the more sparsely, on the contrary, more dense.ScanGenerally used sequence.Overlap(th)1 is generally used, the laser shot timesShapeThe actual shape of the scar selected according to, generally used in the square.

Formal model energy parameter reference tableSingle modePower:(8~15)W,According to adjust the size of the mole the size of the fat particles, generally used 9W.

The residence time: (1.0 ~ 2.5) ms, generally used 1.5ms, the greater the residence time, the laser acts on the skin longer, whereas shorter.Continuous modePoser:(6~9)WPulse modePower:(6~12)W,Generally used 8W, according to the cut of meat the size of a mole skin tolerance and other adjustment

 

Vaginal model energy parameter reference tablePower(W)inside vaginal treatment head:10~20,According to the degree of pain and skin repair their own ability to choose, generally used in 15.

Outside vaginal treatment head:6~9,According to the degree of pain and skin repair their own ability to choose, is generally used 7.Duration(ms)1.0~2.0,1.0 is generally used, the greater the residence time, the laser acts on the skin longer, whereas shorter.Spot size(mm)1.0~2.0,1.0 is generally used, the greater the spacing, the laser effects on the skin point of the more sparsely, on the contrary, more dense.Scarn modelGenerally used in sequenceShot counter(th)1 is generally used, the laser shots time

4. Application

thermal radiation make Mucosa tissue contraction and collagen fibers thereby improving and restructuring vaginal tightening.

1. Shrink vagina: rapid tightening, constriction, lasting firmness.

2. Beautify vagina: dilute pigment, pink labia.

3. Moist vagina: increase secretion, eliminate dryness.

4. Maintenance vagina: deep rejuvenation, prevent aging.

5. To improve sensitivity.

6. Private health, balance PH, improve the internal environment.

Yes! I am Interested

Multifunctional Fractional CO2 Laser With V Care System

REQUEST CALLBACK

Multifunctional Fractional CO2 Laser With V Care System
  • Multifunctional Fractional CO2 Laser With V Care System
  • Multifunctional Fractional CO2 Laser With V Care System
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 3.5 Lakh / UnitGet Latest Price

Product Details:
Minimum Order Quantity1 Unit
Wavelength10600nm
BrandModern Aesthetics

Description:

The thermal radiation make Mucosa tissue contraction and collagen fibers thereby improving and restructuring vaginal tightening funtion.

1. Shrink vagina: rapid tightening, constriction, lasting firmness.

2. Beautify vagina: dilute pigment, pink labia.

3. Moist vagina: increase secretion, eliminate dryness.

4. Maintenance vagina: deep rejuvenation, prevent aging.

5. To improve sensitivity.

6. Private health, balance PH, improve the internal environment

1. Principle Of this Vaginal tightening Machine:

Vaginal tightening laser is the use of water uptake 10600nm gold standard laser, using a three-dimensional lattice technology and 360-degree circular emission perfect combination of technology, to produce 50-70 degrees Celsius in a controlled depth of the vaginal mucosa, stimulate lamina propria and myometrium newborn fibroblasts, and damaged collagen fibers, elastic fibers, such as restructuring, so as to achieve vaginal wall thickening and tightening of the vagina so that firmness, sensitivity enhancement, vagina tight as ever.

Vaginal tightening laser does not produce skin burns due to high temperature, each capable of Homogeneous heat, acting on a few hundred nanometers thickness Mucosa organization.

Application1. Function Of this Vaginal tightening Machine:

thermal radiation make Mucosa tissue contraction and collagen fibers thereby improving and restructuring vaginal tightening.

Specification

Wavength:10600nm

Laser apparatus:

Sealed off laser device simulated by direct current

Optical beam quality:

TEM00

Output power:

40w

Spot size:

0.02~0.05mm2

Aiming beam:

Red semiconductor laser (635nm, less than 5mw)

Beam transport device:

Articulated arm with 7-joint and balance weight

Working mode:

Continuous operation

Output Mode:

Continuous, single pulse, interval pulse and super pulse

Scan scope:

Max 20mmx20mm

Scan graphics:

Circle, triangle, square, rectangle,hexagon, ellipse, line

Scanning Mode:

Random , Normal and Midsplit scan

Scanning speed:

More than 10m/s

Energy:

1- 40W

Distance:

0.1-2.6mm

Cooling system:

air circulation

Weight:

60kg

Dimension:

65*48*117cm

Power:

220V/11V

Yes! I am Interested

 
X


Explore More Products

Contact via E-mail
Contact via SMS
Varun (Proprietor)
Modern Aesthetics
Modern Aesthetics SF 5A-5B, 2nd Floor, Mahalaxmi Metro Tower, C-2,, Sector 4, Vaishali
Ghaziabad - 201010, Uttar Pradesh, India
Call Us: 
Call Response Rate: 81%
Share Us :
F G T L



Home  |   About Us   |  Our Products  |  Site Map  |   Contact Us

© Modern Aesthetics. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited

Modern Aesthetics